Biological Safety Cabinets

Leading Manufacturers, Exporters, Wholesaler, Retailer and Trader of Pro Class II Type A2 Biological Safety Cabinet, Pro Class II Type B2 Biological Safety Cabinet, Pro Class III Type C3 Biological Safety Cabinet, Pro Plus Class II Type A2 Biological Safety Cabinet, Pro Plus Class II Type B2 Biological Safety Cabinet and Pro Plus Class III Type C3 Biological Safety Cabinet from Pune.

MOQ : 1 Piece

Business Type Exporter, Supplier
Brand Name MAC

Preferred Buyer From

Location Worldwide

Features:



  • 30% air exhaust

  • 70% air recirculation

  • HEPA OR ULPA -filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.

  • HEPA OR ULPA -filtered downflow air is a portion of mixed downflow and inflow air from a common plenum.

  • Negative Pressure air surrounding all biological contaminated ducts and plenums.

  • Negative pressure surrounds the work area with double wall plenums for protection.

  • Air drawn through pre-filter is made to pass through highly effective HEPA OR ULPA (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR ULPA filter drastically. Fitted with HEPA OR ULPA Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ.These filters are designed to accommodate higher air flow volume.

  • Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU – 4 / G-4 Grade, with an efficiency of down to 10 micron. These filters can be cleaned by compressed air & also washable.

  • Mounted on heavy tubular stand with lockable castors.

  • Aerodynamic airflow grills maintain safety and prevent blockage

  • U.V and fluorescent interlock available

  • Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue.

  • The sash is counterbalanced for smooth and lightweight operation with the standard opening of 200mm ±10 mm for easier access to work zone and enhanced user safety.


 


Cass II Biosafety Cabinet Protection



  • High velocity air forced through HEPA OR ULPA filters.

  • Filtered air is thrown in the chamber through jet nozzles with a high velocity which in turn disperse particulate matter on all surface.

  • The lower portion of the Air showers suck the contaminated air and allow it to pass to blower supply plenum through pre-filter installed at the base.

  • This process is a continuous process in which air is continuously filtered and recirculated inside the chamber without any exchange with the external environment.


 


Upper & Front Cover


Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.


 


Material Of Construction


Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of CRC sheet duly powder coated OR Stainless Steel (SS-304) (as ordered).


 


Front Window/Sash


Front Sash consists of a toughened transparent glass for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protects user from exposure to harmful Ultraviolet radiation.


 


Drain Trough With Valve


The trough at base is easy to clean and for offloading liquid spillage if any.


 


Decontamination By UV Lamp


UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.


 


Splash Proof Electric Supply Socket


Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.


 


Front Airflow Intake Grid


Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.


 


Floor Stand And Castor Wheels


Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.


 


Controller


These models are provided with Microprocessor Based Digital Controller with LCD display and air velocity sensor to display the air velocity across the work table.


 


Options



  • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).

  • Electronic filter choke alarm (Differential Pressure Monitor).

  • TFT Touch Screen Display Controller with air velocity sensor.

  • Exhaust ducting per running feet.

  • Gas Burner.

  • Spare U.V. Germicidal Tube (1.5 feet).

  • Spare U.V. Germicidal Tube (3.0 feet).

Read More...


Yes! I am interested


MOQ : 1 Piece

Business Type Exporter, Supplier
Brand Name MAC

Preferred Buyer From

Location Worldwide

Features:



  • 100 % air exhaust

  • Negative pressure air surrounding all biological contaminated parts

  • Class II, Type B2 cabinets are total exhaust cabinets, widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.

  • There is no recirculation within the work area.

  • Room air enters through a blower/motor in the top of the cabinet and passes through a HEPA supply filter into the work area as the vertical unidirectional airflow.

  • Descending air is pulled through the base of the cabinet through the perforated front and rear grilles.

  • Simultaneously, air entering through the perforated front opening is pulled through the grille and exhausted immediately,

  • 100% of the air is pulled into the facility exhaust system for appropriate treatment.

  • Type B2 cabinet is hard-connected to an exhaust system.

  • Negative pressure surrounds the work area with double-wall plenums for protection.

  • Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU - 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher air flow volume.

  • Prefilter is made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on the air leaving side; conforms to EU-4 /G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable.

  • Mounted on heavy tubular stand with lockable castors.

  • Aerodynamic airflow grills maintain safety and prevents blockage.

  • U.V and fluorescent interlock available

  • Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue

  • Sash is counterbalanced for smooth and lightweight operation with a standard opening for easier access to the work zone and enhanced user safety.

  • CLASS-II design ensures PERSONNEL, PRODUCT and ENVIRONMENT PROTECTION.


 


Cass II Biosafety Cabinet Protection



  • Personnel protection from harmful agents used inside the biosafety cabinet.

  • Product protection to avoid contamination of the works, experiment or process from outside contaminants.

  • Environmental protection from contaminants contained within the biosafety cabinet.


 


Cass II Biosafety Cabinet Key Features



  • A front access opening with carefully maintained inward airflow.

  • HEPA-filtered, vertical, unidirectional airflow within the work area.

  • HEPA-filtered exhaust air to the room or exhaust to a facility exhaust system.


 


Cass II Biosafety Key Applications



  • Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.

  • The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.

  • All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However, for level 4 Class III cabinets are recommended.


 


Upper & Front Cover


Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.


 


Material Of Construction


Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of electrogalvanized powder coated OR Stainless Steel (SS-304) (as ordered).


 


Front Window/Sash


Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.


 


Drain Trough With Valve


The trough at base is easy to clean and for offloading liquid spillage if any.


 


Decontamination By UV Lamp


UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and the motor blower is turned off/on as and when the front sash is closed/opened. UV lamps function through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.


 


Splash Proof Electric Supply Socket


Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.


 


Front Airflow Intake Grid


Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.


 


Floor Stand And Castor Wheels


Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.


 


Controller


These models are provided with Microprocessor Based Digital Controller with LCD display and air velocity sensor to display the air velocity across the work table.


 


Options:



  • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).

  • Electronic filter choke alarm (Differential Pressure Monitor).

  • TFT Touch Screen Display Controller with air velocity sensor.

  • Exhaust ducting per running feet.

  • Gas Burner.

  • Spare U.V. Germicidal Tube (1.5 feet).

  • Spare U.V. Germicidal Tube (3.0 feet).

Read More...


Yes! I am interested


MOQ : 1 Piece

Business Type Exporter, Supplier
Brand Name MAC

Preferred Buyer From

Location Worldwide

Features:



  • A TOTAL CONTAINMENT CABINET

  • 100% air exhaust

  • The Class-III Biological Safety Cabinet are designed for work with biosafety level 4 high-risk microbiological agents and provides maximum protection to the environment and the worker. It is a gas-tight enclosure with a non-opening, completely sealed, viewing window. Access to the interior of the cabinet is through a double door pass-through “interchange” box. Reversing that process allows for the safe removal of materials from Class III biosafety cabinet.

  • Both supply and exhaust air are HEPA filtered. Exhaust air must pass through HEPA filter. Class III cabinets usually exhaust air back to the laboratory, however, the exhaust air can also be exhausted to the external environment via a dedicated ductwork system. The air exhausted to the environment can also pass through an optional additional level of SAFETY, though not essential, by incineration process (commonly known as Virus burn-out systems). Air Flow is maintained by a dedicated independent (optional) exhaust system exterior to the cabinet, which keeps the cabinet and all associated ducting under negative pressure.

  • Long, gloves and glove parts are attached in a gas-tight manner to ports of the cabinet. Although these gloves restrict movement for the manipulation of the materials isolated inside the cabinet, they prevent the user’s direct contact with the hazardous materials. THE TRADE-OFF IS CLEARLY ON THE SIDE OF MAXIMIZING PERSONAL SAFETY.

  • Negative pressure surrounds the work area with double-wall plenums for protection.

  • Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher air flow volume.

  • Prefilter is made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU – 4 / G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable.

  • Aerodynamic airflow grills maintain safety and prevents blockage.

  • U.V and fluorescent interlock available

  • Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue

  • Sash is sealed and fixed with glove and ports for access to the work zone and enhanced user safety.


 


Cass III Biosafety Cabinet Protection



  • Personnel protection from harmful agents used inside the biosafety cabinet.

  • Product protection to avoid contamination of the works, experiment or process from outside contaminants.

  • Environmental protection from contaminants contained within the biosafety cabinet.

  • Typically used for biosafety level 4 for high-risk biological agents.


 


Cass III Total Containment Cabinets


Class-III biological safety cabinets are gas-light, designed for use with high risk biological agents. Class-III cabinets provide the highest level of personnel, product and environmental protection.


 


Typical Applications Include



  • Working with emerging diseases or diseases marked for near eradication.

  • Weighing and diluting chemical carcinogens.

  • Working with high concentrations of low to moderated risk agents.

  • Working with large amounts of low to moderate risk agents.

  • Use of equipment or instrumentation generating high aerosol volumes.

  • Maximum containment of highly infectious or hazardous experimental materials.

  • An extra level of safety not available in Class I or II cabinets.


 


Cass II Biosafety Key Applications



  • Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.

  • The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.

  • All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However, for level 4 Class III cabinets are recommended.


 


Exhaust System With Blower


With an exhaust system (Option) consisting of heavy-duty and powerful motor blower system, Class III Type biological safety cabinet is able to exhaust 100% potentially contaminated air outside the cabinet & air.


 


Drain Trough With Valve


The trough at base is easy to clean and for offloading liquid spillage if any.


 


Upper & Front Cover


Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.


 


Decontamination By UV Lamp


UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and the motor blower is turned off/on as and when the front sash is closed/opened. UV lamps function through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.


 


Front Window/Sash


Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.


 


Material Of Construction


Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of CRC duly powder coated OR Stainless Steel (SS-304) (as ordered).


 


Front Airflow Intake Grid


Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.


 


Floor Stand And Castor Wheels


Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.


 


Microprocessor Control


These models are provided with Microprocessor Based Digital Controller with LCD display and air velocity sensor to display the air velocity across the work table.


 


Options



  • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).

  • Electronic filter choke alarm (Differential Pressure Monitor).

  • TFT Touch Screen Display Controller with air velocity sensor.

  • Exhaust ducting per running feet.

  • Gas Burner.

  • Spare U.V. Germicidal Tube (1.5 feet).

  • Spare U.V. Germicidal Tube (3.0 feet).

Read More...


Yes! I am interested


MOQ : 1 Piece

Business Type Exporter, Supplier
Brand Name MAC

Preferred Buyer From

Location Worldwide

Features:



  • 30% air exhaust

  • 70% air recirculation

  • HEPA OR ULPA -filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.

  • HEPA OR ULPA -filtered downflow air is a portion of mixed downflow and inflow air from a common plenum.

  • Negative Pressure air surrounding all biological contaminated ducts and plenums.

  • Negative pressure surrounds the work area with double wall plenums for protection.

  • Air drawn through pre-filter is made to pass through highly effective HEPA OR ULPA (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR UPLA filter drastically. Fitted with HEPA OR ULPA Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ.These filters are designed to accommodate higher air flow volume.

  • Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU – 4 / G-4 Grade, with an efficiency of down to 10 micron. These filters can be cleaned by compressed air & also washable.

  • Mounted on heavy tubular stand with lockable castors.

  • Aerodynamic airflow grills maintain safety and prevent blockage

  • U.V and fluorescent interlock available

  • Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue.

  • The sash is counterbalanced for smooth and lightweight operation with the standard opening of 200mm ±10 mm for easier access to work zone and enhanced user safety.


 


Cass II Biosafety Cabinet Protection



  • High velocity air forced through HEPA filters.

  • Filtered air is thrown in the chamber through jet nozzles with a high velocity which in turn disperse particulate matter on all surface.

  • The lower portion of the Air showers suck the contaminated air and allow it to pass to blower supply plenum through pre-filter installed at the base.

  • This process is a continuous process in which air is continuously filtered and recirculated inside the chamber without any exchange with the external environment.


 


Upper & Front Cover


Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.


 


Material Of Construction


Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of CRC sheet duly powder coated OR Stainless Steel (SS-304) (as ordered).


 


Front Window/Sash


Front Sash consists of a toughened transparent glass for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protects user from exposure to harmful Ultraviolet radiation.


 


Drain Trough With Valve


The trough at base is easy to clean and for offloading liquid spillage if any.


 


Decontamination By UV Lamp


UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.


 


Electrical Utilities


Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet. ON/OFF Switches for motor & Lights.


 


Front Airflow Intake Grid


Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.


 


Floor Stand And Castor Wheels


Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.


 


Magnehelic Gauge


Magnehelic Gauge Differential Pressure Gauge (0 – 50 mm: 1 No.) monitor differential pressure across HEPA Filter with respect to ambient. Magnehelic Differential Pressure Gauge to monitor pressure drop across Workarea with respect to ambient.


 


Emergency Stop


Emergency switch for any emergency situation


 


Controller



  • ALL SYSTEM AND CONTROL THROUGH A 3.5” TOUCH SCREEN LCD DISPLAY WITH IN-BUILT DATA LOGGING (REAL TIME) AND USB PORT ON FRONT FACIA FOR DATA DOWNLOAD FOR FURTHER TRANSFER TO PC.

  • Audio – visual alarm for blower tripping and fault acknowledgement.

  • Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)

  • U. V. Light with Hour Meter & interlocking arrangement to put off U. V. light if either side door opens

  • UV Light with Hour Meter

  • Alarm for front door of BSC for safe clear opening


 


Options:



  • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).

  • Electronic filter choke alarm (Differential Pressure Monitor).

  • Exhaust ducting per running feet.

  • Gas Burner.

  • Spare U.V. Germicidal Tube (1.5 feet).

  • Spare U.V. Germicidal Tube (3.0 feet).

Read More...


Yes! I am interested


MOQ : 1 Piece

Business Type Exporter, Supplier
Country of Origin India
Brand Name MAC
Sash Lift Can Be Lifted and Adjusted Manually
Heavy Duty Exhause System Standard Fitted to the System for 100% Exhaust
Electrical Socket Electrical Socket is Provided for Using Small Electrical Devices
Power Supply 220/230 Volts AC supply

Preferred Buyer From

Location Worldwide

Features:



  • 100 % air exhaust

  • Negative pressure air surrounding all biological contaminated parts

  • Class II, Type B2 cabinets are total exhaust cabinets, widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.

  • There is no recirculation within the work area.

  • Room air enters through a blower/motor in the top of the cabinet and passes through a HEPA supply filter into the work area as the vertical unidirectional airflow.

  • Descending air is pulled through the base of the cabinet through the perforated front and rear grilles.

  • Simultaneously, air entering through the perforated front opening is pulled through the grille and exhausted immediately,

  • 100% of the air is pulled into the facility exhaust system for appropriate treatment.

  • Type B2 cabinet is hard-connected to an exhaust system.

  • Negative pressure surrounds the work area with double-wall plenums for protection.

  • Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU - 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher air flow volume.

  • Prefilter is made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on the air leaving side; conforms to EU-4 /G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable.

  • Mounted on heavy tubular stand with lockable castors.

  • Aerodynamic airflow grills maintain safety and prevents blockage.

  • U.V and fluorescent interlock available

  • Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue

  • Sash is counterbalanced for smooth and lightweight operation with a standard opening for easier access to the work zone and enhanced user safety.

  • CLASS-II design ensures PERSONNEL, PRODUCT and ENVIRONMENT PROTECTION.


 


Cass II Biosafety Cabinet Protection



  • Personnel protection from harmful agents used inside the biosafety cabinet.

  • Product protection to avoid contamination of the works, experiment or process from outside contaminants.

  • Environmental protection from contaminants contained within the biosafety cabinet.


 


Cass II Biosafety Cabinet Key Features



  • A front access opening with carefully maintained inward airflow.

  • HEPA-filtered, vertical, unidirectional airflow within the work area.

  • HEPA-filtered exhaust air to the room or exhaust to a facility exhaust system.


 


Cass II Biosafety Key Applications



  • Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.

  • The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.

  • All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However, for level 4 Class III cabinets are recommended.

  • Upper & Front Cover

  • Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.


 


Material Of Construction


Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of electrogalvanized powder coated OR Stainless Steel (SS-304) (as ordered).


 


Front Window/Sash


Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.


 


Drain Trough With Valve


The trough at base is easy to clean and for offloading liquid spillage if any.


 


Decontamination By UV Lamp


UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and the motor blower is turned off/on as and when the front sash is closed/opened. UV lamps function through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.


 


Splash Proof Electric Supply Socket


Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.


 


Front Airflow Intake Grid


Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.


 


Floor Stand And Castor Wheels


Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.


 


Controller



  • All system and control through a 3.5” touch screen LCD display with in-built data logging (real-time) and USB port on front facia for data download for further transfer to pc.

  • Audiovisual alarm for blower tripping and fault acknowledgment.

  • Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)

  • U. V. Light with Hour Meter & interlocking arrangement to put off U. V. light if either side door opens

  • UV Light with Hour Meter

  • Alarm for the front door of BSC for safe clear opening


 


Options



  • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).

  • Electronic filter choke alarm (Differential Pressure Monitor).

  • Exhaust ducting per running feet.

  • Gas Burner.

  • Spare U.V. Germicidal Tube (1.5 feet).

  • Spare U.V. Germicidal Tube (3.0 feet).

Read More...


Yes! I am interested


MOQ : 1 Piece

Business Type Exporter, Supplier
Country of Origin India
Brand Name MAC

Preferred Buyer From

Location Worldwide

Features:



  • A TOTAL CONTAINMENT CABINET

  • 100% air exhaust

  • The Class-III Biological Safety Cabinet are designed for work with biosafety level 4 high-risk microbiological agents and provides maximum protection to the environment and the worker. It is a gas-tight enclosure with a non-opening, completely sealed, viewing window. Access to the interior of the cabinet is through a double door pass-through “interchange” box. Reversing that process allows for the safe removal of materials from Class III biosafety cabinet.

  • Both supply and exhaust air are HEPA filtered. Exhaust air must pass through HEPA filter. Class III cabinets usually exhaust air back to the laboratory, however, the exhaust air can also be exhausted to the external environment via a dedicated ductwork system. The air exhausted to the environment can also pass through an optional additional level of SAFETY, though not essential, by incineration process (commonly known as Virus burn-out systems). Air Flow is maintained by a dedicated independent (optional) exhaust system exterior to the cabinet, which keeps the cabinet and all associated ducting under negative pressure.

  • Long, gloves and glove parts are attached in a gas-tight manner to ports of the cabinet. Although these gloves restrict movement for the manipulation of the materials isolated inside the cabinet, they prevent the user’s direct contact with the hazardous materials. THE TRADE-OFF IS CLEARLY ON THE SIDE OF MAXIMIZING PERSONAL SAFETY.

  • Negative pressure surrounds the work area with double-wall plenums for protection.

  • Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher air flow volume.

  • Prefilter is made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU – 4 / G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable.

  • Aerodynamic airflow grills maintain safety and prevents blockage.

  • U.V and fluorescent interlock available

  • Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue

  • Sash is sealed and fixed with glove and ports for access to the work zone and enhanced user safety.


 


Cass III Biosafety Cabinet Protection



  • Personnel protection from harmful agents used inside the biosafety cabinet.

  • Product protection to avoid contamination of the works, experiment or process from outside contaminants.

  • Environmental protection from contaminants contained within the biosafety cabinet.

  • Typically used for biosafety level 4 for high-risk biological agents.


 


100% Air Exhaust


No air recirculation and the air is exhausted by HEPA filters and to the room directly. If the air needs to be exhausted to outdoors, another out connected duct need to be ordered, and an extra duct and motor blower (option) are required.


 


Complete Negative Pressure


The special design makes interior of cabinet is completely under negative pressure, and sure the HEPA filters, ensures operators security, neither substance nor polluted air will leak out.


 


Pass-Through Negative Pressure


Since it is a gas-tight enclosure with a non-opening, completely sealed, viewing window. Access to the interior of the cabinet is through a double door pass-through “interchange” box. Reversing that process allows for the safe removal of materials from Class-III biosafety cabinet.


 


Cass III Total Containment Cabinets


Class-III biological safety cabinets are gas-light, designed for use with high risk biological agents. Class-III cabinets provide the highest level of personnel, product and environmental protection.


 


Typical Applications Include



  • Working with emerging diseases or diseases marked for near eradication.

  • Weighing and diluting chemical carcinogens.

  • Working with high concentrations of low to moderated risk agents.

  • Working with large amounts of low to moderate risk agents.

  • Use of equipment or instrumentation generating high aerosol volumes.

  • Maximum containment of highly infectious or hazardous experimental materials.

  • An extra level of safety not available in Class I or II cabinets.

  • Exhaust System With Blower

  • With an exhaust system (Option) consisting of heavy-duty and powerful motor blower system, Class III Type biological safety cabinet is able to exhaust 100% potentially contaminated air outside the cabinet & air.


 


Drain Trough With Valve


The trough at base is easy to clean and for offloading liquid spillage if any.


 


Upper & Front Cover


Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.


 


Decontamination By UV Lamp


UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and the motor blower is turned off/on as and when the front sash is closed/opened. UV lamps function through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.


 


Front Window/Sash


Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.


 


Material Of Construction


Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of CRC duly powder coated OR Stainless Steel (SS-304) (as ordered).


 


Front Airflow Intake Grid


Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.


 


Floor Stand And Castor Wheels


Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.


 


Controller


ALL SYSTEM AND CONTROL THROUGH A 3.5” TOUCH SCREEN LCD DISPLAY WITH IN-BUILT DATA LOGGING (REAL TIME) AND USB PORT ON FRONT FACIA FOR DATA DOWNLOAD FOR FURTHER TRANSFER TO PC. Audiovisual alarm for blower tripping and fault acknowledgment. Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)U. V. Light with Hour Meter & interlocking arrangement to put off U. V. light if either side door opensUV Light with Hour MeterAlarm for the front door of BSC for safe clear opening


 


Options:



  • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).

  • Electronic filter choke alarm (Differential Pressure Monitor).

  • Exhaust ducting per running feet.

  • Gas Burner.

  • Spare U.V. Germicidal Tube (1.5 feet).

  • Spare U.V. Germicidal Tube (3.0 feet).

Read More...