Leading Manufacturers, Exporters, Wholesaler, Retailer and Trader of Bowl Sterilizer, Ethylene Oxide Sterilizer, XL Series Ultra High Pressure Autoclave, Vertical Autoclaves, Steam Sterilizers, Horizontal Autoclaves, Table Top Front Loading Autoclaves, Portable Autoclaves and Hydro Thermal Autoclaves from Pune.
Backed with 56 years of service to science and our expertise in steam pressure sterilization autoclaves. Our Top Loading PRO Series Autoclaves are the ideal companion for the modern microbiologists and institutes, pharma companies, hospitals etc.
Leakproof silicon gasket
Over pressure safety
Safe and sturdy chamber manufactured from Stainless Steel (SS-304)
Low water level cut off for safety of heating elements.
Independent safety for over temperature protection.
Saves Power bills by upto 30%
Outer body mild steel OR Stainless Steel SS-304. (as ordered).
Electrical on/off safety switch
Easy draining of chamber
Easy portability and placement and movement
Usage Portability
Single lever locking of lid for faster operations.
Heater and pressure interlock for lid lock safety.
Effortless lifting of lid with assisted spring push back support
Accurate temperature control with user level flexibility. Display process and set values simultaneously.
Microprocessor Based Fully Automatic Fuzzy Logic Control System with Alphanumeric Digital backlit LCD display.
Automatic Steam purging and exhaust
Fitted with AUTOMATIC DIGITAL MINUTE TIMER which starts automatically when set/desired value of temperature is achieved. When the set time period is over the heaters get switched off automatically with alarm for cycle end.
Option
G-LOG – Fully automatic digital (FAD) with real time data logger with CENTRONIC PRINTER PORT (DOT MATRIX) and USB Port for taking data (Paperless Data Recording) and Saving ON PC. (DOT Matrix Printer to customer scope)
P-LOG – Fully automatic digital (FAD) with real time data logger with CENTRONIC PRINTER PORT (DOT MATRIX) and RS-485 PC communication port with 21 CFR compliant software and data cable for logging data directly to your PC. (DOT Matrix Printer and PC to customer scope)
Validation documentation (Mapping) with (3+1) point temperature scanning for one cycle each on empty and loaded conditions (to cost extra)
Drain/Exhaust cooling through a cooling coil condenser for condensate collection.
TFT Touch Screen Display Controller in lieu of LCD display.
Vacuum Pulsing thru a vacuum pump.
Circular Chart Recorder to cost extra (for Temperature)
Circular Chart Recorder to cost extra (for Temperature and Pressure)
“MAC” Vertical Autoclaves are most ideal for all applications requiring, routine total destruction of all living micro-organisms
An Ideal tool for Laboratories, hospitals, nursing homes, R & D labs etc.
Heaters cover stand and carrier/bucket are made of Stainless Steel.
Specially designed system for dry sterilization processes, the system is a triple walled unit with inner chamber, jacked and outer wall made of Stainless Steel.
Lid made of Stainless Steel is closed through a RADIAL LOCKING ARRANGEMENT.
The chamber is leak proof and all joints are duly argon arc welded.
Mounted on mild steel support legs.
The system is supplied without basket and without dressing drum, however the same are available at extra cost.
Lid is fitted with Pressure Gauge, Spring Loaded Safety Valve, Manual Exhaust Valve, Vacuum Breaker-cum-Purge Valve as a safety device and water level indicator.
Drain Valve facilitates easy cleaning of the chamber.
All internal joints are argon arc welded, ground and polished to give crevice free internals.
Operating range from 15 to 20 psi pressure (adjustable).
Industrial grade energy efficient heaters reduce power bills drastically.
To work on 220/230Volts, 50/60 Hz AC supply.
Option:
G-LOG – Fully automatic digital (FAD) with real time data logger with CENTRONIC PRINTER PORT (DOT MATRIX) and USB Port for taking data (Paperless Data Recording) and Saving ON PC. (DOT Matrix Printer to customer scope)
P-LOG – Fully automatic digital (FAD) with real time data logger with CENTRONIC PRINTER PORT (DOT MATRIX) and RS-485 PC communication port with 21 CFR compliant software and data cable for logging data directly to your PC. (DOT Matrix Printer and PC to customer scope)
Validation documentation (Mapping) with (3+1) point temperature scanning for one cycle each on empty and loaded conditions (to cost extra)
Drain/Exhaust cooling through a cooling coil condenser for condensate collection.
TFT Touch Screen Display Controller in lieu of LCD display.
MAC Horizontal Double Walled Autoclaves are most ideal for critical applications requiring assured and reliable total destruction of all living micro-organisms.
An ideal tool for Laboratories, hospitals, nursing homes, R & D labs, etc.
Double walled unit horizontally mounted on a sturdy, heavy M.S. duly painted.
Both inner chamber and outer wall made of S.S.
Pressure is adjustable from 10-20 psi.
Fitted with pressure gauge, safety valve, and steam release valve.
Available with the separate boiler.
For units fitted with S.S. Boiler, separate valves for injecting the steam into the main chamber and releasing the steam in the atmosphere after use are provided.
Automatic vacuum breaker is provided to break the vacuum in case of formation of vacuum due to steam condensation.
Automatic Low Water Level Cut-off Device fitted for the general safety of the element.
Fitted with Automatic Pressure Control Switch.
Fitted with dial thermometer to indicate the inner chamber temperature.
Lid is made of thick machined Stainless Steel plate
Supplied without jacket (Double walled chamber with separate boiler).
Industrial grade energy efficient heaters reduce power bills drastically.
Options:
G-LOG – Fully automatic digital (FAD) with real time data logger with CENTRONIC PRINTER PORT (DOT MATRIX) and USB Port for taking data (Paperless Data Recording) and Saving ON PC. (DOT Matrix Printer to customer scope)
P-LOG – Fully automatic digital (FAD) with real time data logger with CENTRONIC PRINTER PORT (DOT MATRIX) and RS-485 PC communication port with 21 CFR compliant software and data cable for logging data directly to your PC. (DOT Matrix Printer and PC to customer scope)
Digital Temperature Controller with timer can be fixed at an extra cost. Once the temperature is attained it will automatically start the timer. It raises on alarm at a set time, so that operator is alerted & he can perform balance operations
Circular Chart Recorder to cost extra (for Temperature)
Circular Chart Recorder to cost extra (for Temperature and Pressure)
Corrosion resistance, non-spill of hazardous substance, reduce pollution, safety for using.
High and uniform temperature boost helps in quick and easy dissolution of samples containing volatile elements which are difficult to dissolve under normal conditions
Beautiful appearance reasonable structure, easy operation and shorten the analysis time, with reliable data
Contains double care Teflon bush prevents spillage and leakage and thus can contain corrosive acids or alkaline test samples
Easily replaces platinum crucible and helps in solving analysis of trace elements